| 摘要: |
| 通过对汤峪水电站的计算分析,确定当导叶无分段关闭装置时,调压阀流量为1.7m3/s,行程52mm,导叶快关闭时间1.99s,导叶慢关闭时间17.89s;当导叶设有分段关闭装置时,调压阀流量为1.44m3/s,行程44mm,导叶第一段关闭时间1.8s,导叶两段关闭总时间4.42s,即能满足要求。 |
| 关键词: 水电站,压力管道,调压阀,调节参数,调节保证计算 |
| DOI: |
| 分类号:TV732 |
| 基金项目: |
|
| An Analysis of the Operational Reliability of the Pressure Regulating Valve at Tangyu Water Power Station |
|
Feng Shiling Ba Duoduo,Feng Shiling Ba Duoduo
|
| Abstract: |
| By means of calculation and analysis at Tangyu Water Power Station,
some regulated parameters were determined.When the guide vane was not installed with
stage-closing devices,the flow rate of pressure regulating valve was 1.7m3/s,and the
travel was 52 mm with 1.99 s for the fast closing time of the guide vane and 17.895 for
the slow closing time;when the guide vane and operated with stage-closing devices,the
flow rate of the pressure regulating valve was 1.44m3/s,and the travel was 44 mm with
1.85 and 4.425 for the total closing time of the two stages.Both ways could meet the
design requirements |
| Key words: wager power station,pressure pipeline,pressure regulating valve,regulated parameters ,calculation of regulation and guarantee |